Latest / Deep Dive Ortho — Orthopaedic Surgery, AI & Digital Health Podcast. / Ellipse Glenoid Version: Friedman Method Refinement
Transcript
- 0:00Welcome to the deep dive, where we really plunge
- 0:03into the sources, the articles, the research,
- 0:05and pull out those key nuggets of knowledge just
- 0:07for you. Today we're diving into something that
- 0:10sounds maybe a bit niche, but it's actually incredibly
- 0:13vital in modern medicine. We're talking about
- 0:15precision, absolute precision in shoulder surgeries.
- 0:19Imagine for a second you're maybe facing total
- 0:23shoulder arthroplasty, TSA, they call it. It's
- 0:26this major procedure, right, designed to get
- 0:28rid of awful pain, give you back your movement.
- 0:30But the success of that surgery, it really hinges
- 0:34on an almost unbelievable level of accuracy.
- 0:37We're talking replacing parts of your shoulder
- 0:39joint, the socket, the glenoid, getting that
- 0:41angle spot on. You might think, well, how much
- 0:43difference can a few degrees make? But, you know,
- 0:45in the body, especially a joint like the shoulder.
- 0:47Tiny angles, huge consequences. Yeah, think about
- 0:50this. Using some of the older methods, a surgeon
- 0:52might, without even knowing it, place an implant
- 0:55based on a measurement that's off by what the
- 0:57paper suggests, over 14 degrees in some cases.
- 0:5914 degrees. That's massive in this context. Exactly.
- 1:02And that tiny sounding error, it could mean years
- 1:05of pain -free life versus going back under the
- 1:08knife for another really tough, expensive revision
- 1:11surgery. Which nobody wants. Nobody. And this
- 1:13isn't just for surgeons, is it? It's really for
- 1:16anyone curious about how medicine moves forward,
- 1:19how brilliant people are pushing for that accuracy
- 1:21that genuinely changes lives. Absolutely. And
- 1:24what's really remarkable here, I think, is how
- 1:26a seemingly small refinement, just tweaking how
- 1:29you measure something, can have these huge ripple
- 1:31effects. Our mission today is to unpack one of
- 1:34those innovations, a potentially groundbreaking
- 1:38way to measure that shoulder socket angle, the
- 1:40glenoid version. It's called the ellipse modification
- 1:43of the Friedman method. Ellipse modification,
- 1:45okay. And this isn't just theory, it's backed
- 1:47by solid research, a key paper published in the
- 1:49Bone and Joint Journal back in February 2020.
- 1:52And a really crucial contributor to this work,
- 1:55someone instrumental in actually writing the
- 1:57manuscript. So really shaping how the findings
- 1:59were presented, ensuring that scientific rigor
- 2:01is Professor Mo Imam. Professor Imam? Yes, he's
- 2:05based at Ashford in St. Peter's Hospital's NHS
- 2:07Trust. And he's, well, he's a highly prolific
- 2:11researcher. exceptionally cited. We're talking
- 2:14146 publications, over 1 ,100 citations. His
- 2:18input here really speaks volumes about the thought
- 2:20behind this method. That's some serious expertise.
- 2:23It is. And the core idea, the whole point, is
- 2:25that getting that precision before surgery in
- 2:28the planning stage is just vital for success.
- 2:31It directly impacts how well you function afterwards,
- 2:33your quality of life. So what does this all mean
- 2:35for you listening in? Maybe you're not a surgeon,
- 2:37maybe you're not having shoulder surgery, but
- 2:39Understanding this, this relentless drive for
- 2:42getting things exactly right, it gives you real
- 2:44insight into how medicine improves, doesn't it?
- 2:46It really does. We're going to get into why these
- 2:49tiny angles matter so much and how research like
- 2:52this, spearheaded by people like Professor Imam,
- 2:55makes a real difference. It's science refining
- 2:58how we heal. OK, so let's set the stage properly.
- 3:01Let's talk about the stakes in total shoulder
- 3:04arthroplasty because they are incredibly high.
- 3:07TSA, it's a big deal. You're replacing damaged
- 3:10parts. the ball of your upper arm bone, the humerus,
- 3:14and that shallow cup, the glenoid, your shoulder
- 3:16socket, replacing them with artificial parts.
- 3:19Prostetic components, yeah. Think of it like,
- 3:21I don't know, building a house inside your shoulder,
- 3:23high stakes construction. And just like with
- 3:25the house, the foundation, it has to be perfectly
- 3:27level if it's off even a bit. Everything else
- 3:30is compromised. Walls, roof. Exactly. In TSA,
- 3:33that foundation is the glenoid component, this
- 3:36artificial socket they put in. And the main goal,
- 3:38the absolute driver for the... is getting that
- 3:41alignment just right, anatomically correct. That's
- 3:44the key to making the implant last, making sure
- 3:46your shoulder works properly, hopefully for decades.
- 3:50Yeah. Pain -free movement. That's the dream.
- 3:51The dream. And connecting this to the bigger
- 3:54picture. The reason that foundation, that alignment,
- 3:58is so incredibly critical is because glenoid
- 4:00loosening. Well, it's the most common reason
- 4:03why these anatomical shoulder replacements fail.
- 4:06loosening, so the implant comes away from the
- 4:08bone. Essentially, yes. And that's the number
- 4:11one reason patients end up needing revision surgery,
- 4:13a second operation, which is complex, costly,
- 4:18painful, just something everyone wants to avoid.
- 4:21Definitely. And this is where glenoid version
- 4:22comes right into the spotlight. It's basically
- 4:24the angle of that socket. Is it tilted too far
- 4:27forward? That's anti -version? Yeah. Or too far
- 4:29backward? That's retroversion. OK, the tilt.
- 4:32Yeah, the tilt. If that angle isn't right, Even
- 4:34by just a few degrees, it puts abnormal stress
- 4:37on the new implant. Constant, uneven pressure.
- 4:41And over time, that stress can cause the component
- 4:43to slowly work its way loose. Ah, okay. So that
- 4:47slight tilt leads directly to the loosening problem.
- 4:49It's a major contributing factor, absolutely.
- 4:51And these aren't just, you know, theoretical
- 4:52worries from research papers, are they? This
- 4:54stuff is real. It hits patients hard. Devastatingly
- 4:58real. Yeah. and meticulously documented. There
- 5:01are studies, right, like Farron and his team
- 5:04back in 2006. They found if the glenoid was put
- 5:06in more than five degrees too far back, too retroverted.
- 5:09Yeah, more than five degrees retroversion. It
- 5:11led to a seven -fold increase in micromotion.
- 5:14Seven times. Micro ocean. That sounds small,
- 5:18but it's bad, right? It's terrible. Imagine tiny
- 5:21little destructive wobbles where the implant
- 5:22meets the bone. It destabilizes everything. And
- 5:25they also sound a 3 .26 fold increase in stress
- 5:29right at that bone cement interface. It's basically
- 5:32asking for the implant to fail early. Wow. Okay.
- 5:35And then there was Shapiro, 2007. They showed
- 5:38that if you don't correct that backward tilt,
- 5:41that retroversion, you get eccentric loading.
- 5:43Eccentric loading, yeah. Think of it like the
- 5:45forest isn't spread evenly across the implant.
- 5:47It's constantly pushing it off -center. Like
- 5:49leaning on one side of a chair leg constantly.
- 5:51Kind of, yeah. And that leads directly to more
- 5:53wear on the implant material itself. And again,
- 5:55it loosens faster. And even small amounts matter.
- 5:58I think Neifler's group showed that. Yes. Neifler
- 6:00at all. In 2006, they used cadaver models. Very
- 6:04precise. Showed that even tiny steps of retroversion
- 6:07just four degrees at a time, caused the humeral
- 6:10head, the ball part, to shift backward off center.
- 6:13And that led to early loosening in their models.
- 6:15So even small errors add up. They absolutely
- 6:17do. And maybe most importantly for how a patient
- 6:20actually feels and functions, Ye -Yin and colleagues
- 6:23in 2005 found a direct link. More retroversion
- 6:27in the implant. Significantly lower constant
- 6:29scores. The constant score, that measures shoulder
- 6:32function, right? Pain, movement. Exactly. It's
- 6:34a standard measure. Lower scores mean more pain,
- 6:37less movement, basically a shoulder that doesn't
- 6:39work well for everyday things, reaching up, getting
- 6:42dressed. So we're not just talking about implants
- 6:44revival here. We're talking about real day -to
- 6:46-day pain and limitation for the patient and
- 6:49potentially needing another operation. Precisely.
- 6:52And while, sure, other things play a role, patient
- 6:54factors like age, sex. the implant design itself,
- 6:58getting that glenoid position right, that's a
- 7:00huge factor. And crucially, it's something the
- 7:03surgeon can control. It's controllable. That's
- 7:05the key. It is. It's a critical moment in the
- 7:07OR where accurate measurement can literally change
- 7:11the patient's future. OK, so the stakes are sky
- 7:14high. Getting that angle right is non -negotiable,
- 7:18which brings us to the obvious question. How
- 7:21do surgeons measure it accurately? You mentioned
- 7:24CT scans. Regular x -rays aren't enough. No.
- 7:28Conventional x -rays just don't give you the
- 7:30detail you need for version. You absolutely need
- 7:33a CT scan, computed tomography. It gives you
- 7:35those cross -sectional slices. Right. But even
- 7:37with CT scans, you said there's no single best
- 7:41way everyone agrees on. That's the surprising
- 7:43thing. There isn't universal consensus. Different
- 7:45techniques exist. But one thing everyone does
- 7:48agree on is that the CT scans must be properly
- 7:51reformatted. Reformatted? What does that mean?
- 7:53It means digitally realigning the images so you're
- 7:55looking squarely at the shoulder blade, the scapula,
- 7:57and its natural plane. You remove any tilt or
- 8:00rotation from how the scan was taken. It's called
- 8:02the scapula plane reformat. OK, so you have to
- 8:05get the image lined up perfectly first. Absolutely.
- 8:07If you don't do that basic step right, any measurement
- 8:10you take afterwards is basically garbage. It
- 8:12won't be accurate or reproducible. Got it. Foundational
- 8:15step. So assuming you've got your properly reformatted
- 8:19CT, what's been the main method people use? Historically,
- 8:23and still very common because it's relatively
- 8:25straightforward, the go -to has been the Friedman
- 8:28method, described way back in 1992 by Friedman
- 8:31and his colleagues. Friedman method. OK. How
- 8:34does that work? It uses a bony landmark called
- 8:37the coracoid process. It's this hook -like bone
- 8:40sticking off the front of your shoulder blade.
- 8:42You find that, and then you measure the glenoid
- 8:44version on an axial slice, a cross section that's
- 8:4710 millimeters below it. 10 millimeters below
- 8:49the coracoid? Seems specific. It is specific.
- 8:52Yeah. But, and here's the crucial but, if it's
- 8:55so widely used, what's the problem? Why bother
- 8:57developing something new like Professor Imam
- 8:59and his co -authors did? Yeah, good question.
- 9:01What's the catch? The catch is the coracoid itself.
- 9:04Ah, the reference point. Exactly. And this is
- 9:07where the paper we're looking at gets really
- 9:09interesting and where the ellipse method comes
- 9:10in. The paper points out quite directly that
- 9:14the coracoid process is highly variable. Variable
- 9:18how? Like shape? Position? Both. Its shape can
- 9:23differ quite a bit between people. and critically,
- 9:26its exact position relative to the actual glenoid
- 9:29socket isn't consistent. So if your landmark
- 9:31moves around... Your measurement starting point
- 9:33moves around. It makes it really hard to consistently
- 9:35find what everyone agrees is the true mid -glenoid
- 9:39level. Mid -glenoid level. Why is heading that
- 9:42exact middle point so important? Because the
- 9:44glenoid version... that angle we care so much
- 9:46about. It actually changes along the face of
- 9:48the socket. It's not the same angle top to bottom.
- 9:50Really? It varies. Oh, yeah. Typically, the upper
- 9:53part of the glenoid is more retroverted, tilted
- 9:56back, more than the middle part of the true equator.
- 9:58Ah, OK. So if you measure too high or too low
- 10:02because your coracoid landmark put you in the
- 10:04wrong spot. You get a skewed measurement. You
- 10:06might think the version is, say, 10 degrees retroverted,
- 10:09but the true version at the middle might only
- 10:11be five degrees. or vice versa. You're measuring
- 10:14the wrong slice, essentially. And that inconsistency,
- 10:18that reliance on a variable landmark, that's
- 10:20the Achilles heel of the Friedman method. That's
- 10:23exactly what the authors argue. It introduces
- 10:25this inherent variability that surgeons have
- 10:28just had to kind of deal with. Now there are
- 10:30other methods, sure, Randelli's method, Poonin
- 10:33-Ting's vault method for... tricky cases. But
- 10:35Friedman's has been the most popular. Generally,
- 10:38yes, because it seems relatively easy to apply,
- 10:40which makes this variability problem even more
- 10:43significant. You know, it highlights why a more
- 10:46reliable way to find that mid -glenoid level
- 10:48was really needed. And what's really cool about
- 10:50the ellipse method is where it came from. It
- 10:53wasn't just dreamt up in a lab somewhere. It
- 10:55came directly out of the clinical trenches, you
- 10:57could say. The authors, including Professor Mo
- 11:00Imam, who, remember, was key in actually writing
- 11:02this paper, articulated the findings they were
- 11:04facing, these exact limitations of the Friedman
- 11:06method, day in, day out in their own surgical
- 11:09practice. They were living the problem. Exactly.
- 11:11And especially with newer digital imaging, where
- 11:14you can see the axial and sagittal views cross
- 11:17-section and side view side by side simultaneously.
- 11:20Ah, that must make the inconsistencies more obvious.
- 11:23It really does. You start seeing how relying
- 11:25on just the coracoid isn't always hitting the
- 11:29same spot relative to the glenoid itself. So
- 11:32their goal became really clear. Find a way to
- 11:36consistently, reliably nail down that mid -glenoid
- 11:38level every single time. Not just guess, or hope
- 11:41you're in the right place. Precisely. It wasn't
- 11:43about totally changing how you measure the angle
- 11:46between the lines, but about making sure where
- 11:48you draw those lines is standardized and accurate.
- 11:50picking the guesswork out. OK, so let's unpack
- 11:52it. How does this ellipse method actually work?
- 11:54Walk us through the steps. It sounds like a visual
- 11:56journey. It is, and it's actually quite elegant
- 11:58once you break it down. It's basically five steps
- 12:00using those modern CT views. Step one, you start
- 12:04with the sagittal view, the side view of the
- 12:05shoulder. And on that view, you draw what they
- 12:09call a best fit ellipse. Right around the entire
- 12:11glenoid fossa, top to bottom. Like putting an
- 12:14oval picture frame around the socket from the
- 12:17side. That's a perfect analogy. You capture the
- 12:19whole vertical extent. That ellipse becomes your
- 12:22geometric guide. Step two. Step two. Measure
- 12:25the vertical diameter of that ellipse you just
- 12:27drew. The total height. Simple measurement. Got
- 12:30it. Full height. Step three. Step three. Calculate
- 12:34the exact midpoint of that vertical diameter.
- 12:37Just divide the height by two. That gives you
- 12:39the precise vertical center of the glenoid in
- 12:42that side view. The geometric middle, not based
- 12:44on a wobbly bone landmark. Exactly. That's the
- 12:46key innovation. Use this geometry, not variable
- 12:49anatomy, to find the center. Clever. Okay, step
- 12:52four. Step four. Now, you use the power of the
- 12:55linked views. You find the axial slice, the cross
- 12:58-sectional view, that corresponds exactly to
- 13:00that calculated midpoint you found on the sagittal
- 13:02view. You scroll through the axial slices until
- 13:05you hit the one that lines up perfectly with
- 13:06your midpoint marker. Ah, so the sagittal view
- 13:09guides you to the correct axial slice. Precisely.
- 13:12That specific slice is your defined, consistent,
- 13:15reproducible mid -glenoid level. Found it. No
- 13:18more ambiguity. And step five. Step five. Now
- 13:23that you're confidently on the right axial slice,
- 13:26you measure the glenoid version, and you use
- 13:29the exact same landmarks as the original Friedman
- 13:31method. You draw the glenoid line across the
- 13:34socket face. You draw the scapular axis line.
- 13:37And measure the angle between them. Correct.
- 13:39So the angle measurement itself is familiar,
- 13:41but the plane you're measuring it on is now defined
- 13:43with much, much greater consistency thanks to
- 13:47that ellipse. Okay, let me make sure I've got
- 13:48this. It's not a totally new angle measurement,
- 13:51but a much, much better way of making sure you're
- 13:54measuring that angle at the right spot, the true
- 13:57middle of the glenoid every single time. You've
- 13:59got it. It refines Friedman by fixing its biggest
- 14:01weakness. Finding the correct level reliably,
- 14:04it gives it a stable geometric foundation. That
- 14:07makes a lot of sense. And this leads to a really
- 14:09important question. What does this mean, practically,
- 14:12for the surgeon in the operating room? Yeah,
- 14:14beyond just a better number on a planning sheet.
- 14:17Well, finding that true mid -glenoid level accurately,
- 14:21it doesn't just help plan. It gives the surgeon
- 14:24a much clearer picture of the ideal entry point
- 14:28for the central guide wire when they're actually
- 14:30putting the glenoid component in. The first pin
- 14:32they place to guide the implant. Exactly. The
- 14:35paper calls it intraoperative corroboration.
- 14:38It means the surgeon has a better map during
- 14:40the surgery itself. They could be more confident
- 14:43they're aiming for the right spot, the center
- 14:45they identified in planning. So it connects the
- 14:47plan to the action much more reliably. That's
- 14:50the idea. Potentially fewer errors in placement,
- 14:54better positioning of the actual implant, it
- 14:56builds that bridge between planning and doing.
- 14:58Okay, so the message sounds elegant, logical.
- 15:01Very clever, actually. But how did they prove
- 15:03it works? How did they test it rigorously? Right.
- 15:05The study design. This was a retrospective study,
- 15:07meaning they went back and looked at data that
- 15:09already existed. Sedation scans already done.
- 15:11Exactly. They pulled up 100 CT scans from 100
- 15:14different patients who were all getting their
- 15:16first primary shoulder replacement. So a good
- 15:18size group. An irrelevant group, the actual patients
- 15:21who need this. Definitely. It was a mix, 58 women,
- 15:2442 men, average age around 65, 66, but ranging
- 15:28all the way from 19 to 93. So it captured that
- 15:31typical TSA demographic pretty well. And the
- 15:33stands themselves, they made sure they were suitable?
- 15:36Oh, absolutely crucial. They used a standard
- 15:38protocol, thin, one millimeter slices through
- 15:40the glenoid. And importantly, they ensured all
- 15:44scans were properly reformatted into that scapula
- 15:47plane we talked about. Giving the alignment right
- 15:48from the start. Essential. They also had clear
- 15:51rules for who was in and who was out inclusion
- 15:53-exclusion criteria. Had to be adults, first
- 15:57-time TSA, needed a good quality CT scan available
- 16:00digitally. And who did they exclude? People who'd
- 16:03already had shoulder replacements or surgery
- 16:05on their scapula, anyone whose bones weren't
- 16:07fully mature, or if the CT scan was just technically
- 16:10inadequate, not properly reformatted, didn't
- 16:13show the whole shoulder blade, that sort of thing.
- 16:15So they were careful to compare like with like,
- 16:18making sure the data was clean. Very careful.
- 16:20That's vital for results you can trust. Okay,
- 16:22so they had the scans. Who did the measuring
- 16:25and how? Two senior observers did the measurements.
- 16:28The paper calls them SJ and SH. Experienced clinicians
- 16:32who know how to read these scans. And they both
- 16:35measured glenoid version using the classic Friedman
- 16:37method and the new ellipse method on all 100
- 16:40scans. So a direct comparison on the same patients.
- 16:43Both methods, both observers, okay. But they
- 16:45added another layer of rigor, observer 1, SJ.
- 16:49They measured Friedman once, but they measured
- 16:52using the ellipse method twice. Twice. Why? With
- 16:55a one -month gap between the two measurements.
- 16:57This was to test intra -rater reliability. How
- 17:00consistent is the same person using the ellipse
- 17:02method over time? Do they get the same result
- 17:05if they measure again later? Yeah, checking for
- 17:07drift or inconsistency in one person's measurements.
- 17:10Smart. Very smart. And observer two, SH, measured
- 17:13the ellipse method once. So this whole setup
- 17:15allowed them to look at everything. Likewise.
- 17:16Well, comparing ellipse versus Friedman directly.
- 17:19Comparing observer 1 versus observer 2 using
- 17:23the ellipse method that's iterator reliability.
- 17:26Consistency between different people. And comparing
- 17:29observer one's first ellipse measurement to their
- 17:31second Heller, that's the inter -rater reliability
- 17:33we just talked about. Wow, okay. That's thorough.
- 17:36Covering all the bases for reliability. Extremely
- 17:39thorough. It's how you really build confidence
- 17:41in a new measurement technique. So they had all
- 17:43these measurements. How did they analyze the
- 17:45numbers? What stats did they use? They used a
- 17:47solid statistical toolkit to really dig into
- 17:50what the numbers meant. First, a paired t -test.
- 17:53This basically checks if the average difference
- 17:56between two sets of measurements like Ellipse
- 17:58versus Friedman or Observer 1 versus Observer
- 18:002 is statistically significant. Is the difference
- 18:02likely real or just random chance? Okay, average
- 18:05difference. Then, critically, they use bland
- 18:07Altman plots. These are brilliant for looking
- 18:10at agreement between methods. Instead of just
- 18:12averages, it plots the difference between two
- 18:15measurements for each patient against the average
- 18:17of those two measurements. So you see the spread.
- 18:19How much individual measurements might disagree?
- 18:21Exactly. It visually shows you the range of disagreement.
- 18:25Are the methods generally close across the board,
- 18:27or do they sometimes differ wildly? You look
- 18:30for the limits of agreement on the plot. Narrow
- 18:33limits mean good agreement. Wide limits? Not
- 18:36so much. Okay, Bland -Altman for agreement. What
- 18:39else? The Interclass Correlation Coefficient,
- 18:41or ICC. This gives you a single number between
- 18:440 and 1 that quantifies reliability or consistency.
- 18:48Higher is better. In this study, they defined
- 18:500 .90 or above as excellent. ICC for reliability.
- 18:54Got it. And finally, the repeatability coefficient.
- 18:57This gives you a practical number. It tells you
- 18:59how much difference you'd expect to see between
- 19:01two measurements made by the same person using
- 19:03the same method. 95 % of the time. A smaller
- 19:06number means better repeatability, higher precision.
- 19:09So t -test for significance, bland Altman for
- 19:11agreement spread, ICC for overall reliability,
- 19:15and repeatability for single user precision.
- 19:17That's comprehensive. It really is. And one more
- 19:19crucial thing. They defined beforehand what they
- 19:23considered clinically significant. Ah, not just
- 19:25statistically significant, but actually mattering
- 19:28in practice. Exactly. For this study, they set
- 19:30that threshold at a difference greater than plus
- 19:33or minus five degrees between methods. Five degrees.
- 19:36Why five? That's generally considered a threshold
- 19:38in orthopedics, where the difference is large
- 19:41enough that it might actually change the surgeon's
- 19:43plan, affect implant choice, positioning strategy
- 19:46and potentially impact the patient's outcome.
- 19:48Okay. So they had a clear line in the sand for
- 19:51what really matters clinically. Yes. It allows
- 19:54them to interpret the statistical results in
- 19:56a really practical, meaningful way for surgeons
- 19:59and patients. All right. The moment of truth.
- 20:01They did all this careful work. What did the
- 20:04numbers actually show? Let's start with the average
- 20:06differences. Friedman versus ellipse. OK, so
- 20:09the average glenoid version measured by the traditional
- 20:12Friedman method was maggots of 3 .11 degrees.
- 20:16That negative means retroversion tilted slightly
- 20:18back. OK, average Friedman minus 3 .11. The average
- 20:22measured by the ellipse method using observer
- 20:241's data was minus the 1 .95 degrees retroversion.
- 20:28Minus 1 .95, so slightly less retroverted on
- 20:31average with the ellipse method. On average,
- 20:34yes. The mean difference between Ellipse and
- 20:37Friedman was 1 .16 degrees. And statistically,
- 20:40this difference was significant. The p -value
- 20:42was 0 .002. OK, 1 .16 degrees difference on average,
- 20:47and statistically significant. But you hinted
- 20:50earlier that the average isn't the full story,
- 20:52right? Not even close. This is exactly where
- 20:55it gets really interesting and why those bland
- 20:57Altman plots are so vital. That 1 .16 degree
- 21:01average difference. Honestly, it might sound
- 21:03pretty small. Maybe not clinically huge on its
- 21:05own. Yeah, you might think, okay, about a degree,
- 21:07maybe not a disaster. Right. But that average
- 21:10hides the spread. It tells you nothing about
- 21:12how much the methods might disagree for an individual
- 21:14patient. And that's where the blind Altman plot
- 21:16comes in, comparing Ellipse versus Friedman.
- 21:19Exactly. And the results there were... Well,
- 21:21quite startling, actually. The 95 % limits of
- 21:23agreement were huge. They ranged from minus 6
- 21:26.15 degrees all the way up to plus 8 .46 degrees.
- 21:30Oh, minus 6 to plus 8 .5. What does that mean,
- 21:33practically? It means. OK, let's say the ellipse
- 21:36method measures a patient's glenoid at exactly
- 21:390 degrees version. The Bland -Altman plot tells
- 21:42us that for that same patient, the Friedman method
- 21:45could, 95 % of the time, report value anywhere
- 21:48between meganis 6 .15 degrees and plus 8 .46
- 21:52degrees. That's a potential range of almost 15
- 21:55degrees for the same shoulder, depending only
- 21:57on which method you used. Precisely. That represents,
- 22:01in the author's words, and by any clinical standard,
- 22:04poor... agreement. The two methods might be close
- 22:07on average, but for any given patient, they could
- 22:09give you wildly different numbers. And that could
- 22:11lead to totally different surgical decisions
- 22:13for the same person. Absolutely. And remember
- 22:15that five degree threshold for clinical significance.
- 22:17Yeah. The study found that in 16 % of the patients,
- 22:2016 out of 100, the difference between the ellipse
- 22:23measurement and the Friedman measurement was
- 22:25more than five degrees. 16%. Nearly one in five
- 22:28patients had a clinically significant difference
- 22:30depending on the method used. Yes. For almost
- 22:33a fifth of these patients, the choice of measurement
- 22:36method could have directly led to a different
- 22:38surgical plan, potentially impacting their outcome.
- 22:41It really drives home how much finding a consistent
- 22:43method matters. Wow. Okay, so poor agreement
- 22:46between the methods, but how did the ellipse
- 22:48method perform on its own? You mentioned they
- 22:50tested its internal consistency. Ah, now that's
- 22:53where the story flips. In stark contrast to the
- 22:56poor agreement with Friedman, the ellipse method
- 22:58showed excellent reliability and reproducibility,
- 23:01both between observers and within the same observer.
- 23:04Okay, let's break that down. First, between the
- 23:06two observers, interrater reliability. Right.
- 23:08Comparing observer 1 and observer 2, using the
- 23:11ellipse method, the mean difference between them
- 23:13was tiny. It's just... 0 .063 degrees, not statistically
- 23:18significant at all. Basically, they got the same
- 23:20average result. Good start. And the bland Altman
- 23:22limits for ellipse between observers? Were they
- 23:25wide, like before? Remarkably narrow. The 95
- 23:28% limits of agreement were only 1 .98 to plus
- 23:322 .0 degrees. Minus 2 to plus 2. So 95 % of the
- 23:36time, two different surgeons using the ellipse
- 23:40method would get a result within about two degrees
- 23:42of each other for the same patient. Exactly.
- 23:44That's excellent agreement. Much, much better
- 23:46than the nearly 15 degree range we saw when comparing
- 23:49with Friedman. Okay. And the ICC value for that?
- 23:52The interclass correlation coefficient for iterator
- 23:54agreement was 0 .993. 0 .993. That's way above
- 23:59the 0 .90 threshold for excellent. Absolutely.
- 24:02It indicates excellent reproducibility between
- 24:04different users. Fantastic. Okay, now what about
- 24:06iterator? The same observer measuring twice a
- 24:09month apart. Even better, actually. Observer
- 24:111, measuring the same scans twice with the ellipse
- 24:14method. The mean difference was minuscule. 9
- 24:16is 0 .8 or 41 degrees. Again, not statistically
- 24:19significant. Almost zero difference on average.
- 24:22Pretty much. And then 95 % limits of agreement.
- 24:24Even tighter. From 9 is .98 degrees to plus .90
- 24:27degrees. Less than one degree variation 95 %
- 24:31of the time if the same person measures again.
- 24:33Incredible, isn't it? That's superb precision.
- 24:36And the repeatability coefficient confirmed this.
- 24:38It was 0 .94 degrees, meaning 95 % of repeated
- 24:42measurements by the same person will differ by
- 24:45less than one degree. Wow. And the ICC for IntraRater?
- 24:48Almost perfect. 0 .999. OK, so to summarize,
- 24:52ellipse versus Friedman. Poor agreement, potentially
- 24:55large clinically significant differences, but
- 24:57ellipse versus ellipse, whether between users
- 24:59or by the same user over time. Excellent agreement,
- 25:03highly reproducible, very precise. That's the
- 25:05core finding in a nutshell. The ellipse method
- 25:08demonstrated a level of reliability that the
- 25:10traditional Friedman method simply couldn't match
- 25:12in this study. So this really raises the question,
- 25:14doesn't it? What could this level of proven precision
- 25:17mean for actual shoulder surgery moving forward?
- 25:21It suggests we now have a tool, a method, that
- 25:23can provide a much more trustworthy and consistent
- 25:26number for that critical glenoid version angle.
- 25:29You can standardize planning, reduce variability
- 25:31between surgeons, and give everyone more confidence
- 25:34in that initial assessment. And that confidence
- 25:36should, hopefully, translate into better surgical
- 25:39execution and, ultimately, better patient outcomes.
- 25:43Okay, let's zoom out a bit. Let's talk broader
- 25:45context and really hammer home the so what of
- 25:48all this The main message from the paper then
- 25:51isn't just here's a new method It's that the
- 25:54real breakthrough is having a reliable way to
- 25:57find that mid glenoid level, right? That's what
- 25:59the authors including professor Imam in his writing
- 26:02really emphasize They call consistently defining
- 26:05that mid glenoid level the most important step
- 26:08for getting accurate 2d CT measurements of version
- 26:10and it's so important because Other ways of trying
- 26:13to find it, like just counting slices down from
- 26:15the top or something. Yeah. They just weren't
- 26:16reliable enough. Exactly. The paper cites another
- 26:19study, Vandebunt et al., from 2015, that tried
- 26:22a slice counting method. Their ICC for reliability,
- 26:25only .70. .70 versus the ellipse method's .993
- 26:31between observers. That's a night and day difference
- 26:34in reliability. It really is. It shows the ellipse
- 26:37method isn't just a small tweak. It's a significant
- 26:40leap in consistency. It takes the ambiguity out
- 26:44of where you measure, ensuring everyone's looking
- 26:46at the same anatomically relevant spot. Right.
- 26:49Getting everyone on the same page measurement
- 26:51-wise. And this touches on something else. The
- 26:53paper highlights the importance of using the
- 26:55right statistical tools and using them together.
- 26:58The Bland -Altman plots and the ICCs. Yes. Professor
- 27:01Imam and his co -authors stress this point in
- 27:03the manuscript. The Bland -Altman shows you the
- 27:06side of the differences, the practical agreement.
- 27:08The ICC gives you that overall reliability number.
- 27:11Using both gives you a much better picture of
- 27:14the true reliability. So you see not just if
- 27:17they're correlated, but how well they actually
- 27:19agree within limits that matter clinically. Precisely.
- 27:22It's about robust science. Not just finding a
- 27:24difference, but understanding its magnitude and
- 27:26consistency. That kind of methodological rigor
- 27:29is just as important as the clinical idea itself.
- 27:33Absolutely. And you mentioned this study's reliability
- 27:35for the ellipse method was better than what other
- 27:37studies found when comparing Friedman to other
- 27:39methods like Randellis or the vault method. That's
- 27:42right. Comparing the ICCs reported here for the
- 27:45ellipse method, those high 0 .99 values, with
- 27:49ICCs reported in studies by Rouleau et al. comparing
- 27:52Friedman and Randalli, or Mezzimora at all, comparing
- 27:54Friedman and Valt, the ellipse method demonstrated
- 27:57superior consistency in this particular investigation.
- 28:00It really seems to set a new benchmark for 2D
- 28:03measurement liability. OK. But what about 3D?
- 28:06We hear a lot about 3D planning and surgery now.
- 28:10Does this 2D ellipse method still matter in the
- 28:13age of 3D? That's a really important question.
- 28:15And the paper acknowledges 3D reconstruction.
- 28:17For really complex cases, severe deformities,
- 28:203D planning is often seen as the benchmark. It
- 28:21gives you that full volumetric picture. But it
- 28:24has limitations for routine, everyday use right
- 28:27now. It's generally expensive, needs special
- 28:29software, powerful computers. It requires significant
- 28:32training and expertise to use properly. OK. Cost
- 28:35and training hurdles. And even with 3D, there's
- 28:38still user variability. The surgeon still has
- 28:41to define reference points and axes on the 3D
- 28:44model, which can introduce inconsistencies. Ah,
- 28:47so 3D isn't automatically perfect either. Not
- 28:49necessarily. And maybe the biggest point is the
- 28:52direct link between using 3D planning and actually
- 28:55achieving better long -term clinical outcomes
- 28:58for patients, like lower revision rates, better
- 29:00function scores, years later that link. still
- 29:03needs more robust, independent proof across the
- 29:06board. So the jury's still out on whether 3D
- 29:08consistently leads to better results yet? The
- 29:11evidence is still building. And until we have
- 29:13that definitive proof, and maybe until 3D becomes
- 29:15more accessible and standardized, having a really
- 29:18accurate, reliable 2D measurement, a precise
- 29:21numerical angle remains incredibly important.
- 29:23Why? Why keep focusing on the 2D number? For
- 29:26clear communication between surgeons. For comparing
- 29:28results in research studies effectively. for
- 29:31tracking outcomes over time. You need that consistent,
- 29:34quantifiable angle. And that's exactly what the
- 29:36highly reliable ellipse method provides. It fills
- 29:39a crucial need, even as 3D evolves. Okay, that
- 29:42makes sense. So, let's boil it down. What's the
- 29:45absolute core take -home message from Professor
- 29:48Imam and the other authors of this paper? They
- 29:51really drive home three key points. One... Getting
- 29:55that preoperative glenoid version measurement
- 29:57right is absolutely crucial for planning and
- 30:00executing a successful TSA. It's foundational.
- 30:03Non -negotiable first step. Two, if you have
- 30:06a good quality CT scan that includes the whole
- 30:08scapula and is properly reformatted in the scapular
- 30:12plane, the ellipse method is a highly reproducible
- 30:15and reliable way to find the true mid -glenoid
- 30:18level. That's its unique strength. Reliable identification
- 30:20of the mid -glenoid. And three, Measuring version
- 30:23at that specific mid -glenoid level refines the
- 30:26old Friedman method. It gives you an accurate
- 30:282D angle measurement, plus it crucially shows
- 30:30the surgeon the ideal spot for that central guide
- 30:33wire during surgery. It offers that valuable
- 30:35intraoperative corroboration. So better planning
- 30:37and more confidence during the actual operation.
- 30:40That's the promise. Precision translating into
- 30:42practice. Now good science always acknowledges
- 30:44its limits, and this study is no exception. The
- 30:47authors are upfront about the limitations. OK,
- 30:49what are the main ones we should keep in mind?
- 30:51Well, first and foremost, this all hinges on
- 30:54having that CT scan correctly oriented and reformatted
- 30:58in the scapular plane to begin with. Right, the
- 31:00foundational step we talked about. Exactly. If
- 31:03that basic requirement isn't met, if the initial
- 31:06imaging isn't done right, then even the ellipse
- 31:09method will give you an erroneous measurement.
- 31:12It's not magic. It relies on good data in. So
- 31:15the quality of the initial scan is paramount.
- 31:17That could be a practical hurdle for widespread
- 31:20use if imaging protocols aren't standardized
- 31:23everywhere. It certainly could be. It highlights
- 31:26the need for consistent, high -quality imaging
- 31:28standards if we want to leverage methods like
- 31:30this effectively across different hospitals and
- 31:33clinics. Okay. What else? The study was retrospective.
- 31:35They looked back at past data. Right. So they
- 31:38couldn't directly compare patient outcomes. Correct.
- 31:40Because they were looking at scans that had already
- 31:42been done, they couldn't say, OK, group A was
- 31:44planned with ellipse, group B with Friedman,
- 31:46and group A had fewer revisions five years later.
- 31:49They could only assess the reliability of the
- 31:51measurements themselves. But they do argue that
- 31:53better planning generally leads to better outcomes,
- 31:56right? Yes. There's a strong consensus in orthopedics
- 31:59that accurate planning improves results. But
- 32:02to directly prove that the ellipse method causes
- 32:05better long -term outcomes would require a future
- 32:08prospective study. Following patients forward
- 32:10in time. Exactly. Comparing groups planned with
- 32:13different methods and tracking their function,
- 32:16pain scores, implant survival rates over several
- 32:18years. That's the next logical step in research.
- 32:21Got it. Any other limitations or maybe strengths
- 32:24to balance those? A key strength was that they
- 32:27used consecutive CT scans. They didn't cherry
- 32:30pick easy or hard cases. They took the scans
- 32:32as they came. representing the real mix of patients'
- 32:35assurgencies. That makes the findings on measurement
- 32:38reliability much more generalizable. So it reflects
- 32:41real -world practice better. Yes. And they also
- 32:44noted that the ellipse method seemed usable even
- 32:46when the glenoid was significantly deformed,
- 32:49which adds to its potential versatility. Okay.
- 32:52So, thinking about all this... What does it mean
- 32:55for you, the listener, looking ahead? We've seen
- 32:57how this, well, quite elegant refinement in measurement,
- 33:01driven by clinical need and rigorous research
- 33:03involving experts like Professor Imam, can boost
- 33:06precision. Where does that lead? Well, you start
- 33:09to think about the knock -on effects, don't you?
- 33:11Like how it might change training. Could this
- 33:14become the standard way orthopedic residents
- 33:16are taught to assess glenoid version, making
- 33:19this level of precision just standard practice
- 33:22from day one? It certainly could influence curriculum
- 33:24development, yeah. Standardizing the approach.
- 33:26Then what about technology? Could this method
- 33:29be built into surgical planning software? Maybe
- 33:32even automated with AI to measure a version super
- 33:34consistently, taking human variability out even
- 33:37further? That's a definite possibility. Integrating
- 33:39validated, reliable methods into software is
- 33:42a clear pathway for innovation, reducing potential
- 33:45for error. And the big picture. If this leads
- 33:48to more accurate surgery, fewer implants failing
- 33:51early, what about the savings for health care
- 33:53systems, fewer expensive revision surgeries?
- 33:56That's a potential long -term benefit. Absolutely.
- 33:58Better outcomes often mean lower overall costs
- 34:01down the line. So it leaves you wondering, doesn't
- 34:03it? What's the next piece of research you'd want
- 34:06to see? Is it that direct link to patient outcomes?
- 34:10Studies quantifying fewer revisions, faster recovery,
- 34:13better long -term comfort, specifically because
- 34:15the ellipse method was used. Those outcome studies
- 34:18are definitely key. Connecting the improved measurement
- 34:20directly to improve patient lives is the ultimate
- 34:23goal. It really shows how this constant push
- 34:26for precision, even in something as specific
- 34:28as measuring an angle, is what drives medicine
- 34:31forward, aiming for that perfect outcome one
- 34:34step at a time. Well, that was a truly deep dive,
- 34:36wasn't it, into orthopedic precision, medical
- 34:38innovation, how research like the paper co -authored
- 34:42and articulated by Professor Mo Imam can take
- 34:44an existing method and just refine it, make it
- 34:46so much more reliable, potentially leading to
- 34:49really significant improvements for patients.
- 34:50Yeah, we went from understanding why glenoid
- 34:52loosening is such a critical issue in shoulder
- 34:55replacements through the problems with older
- 34:57measurement methods, right, to this elegant ellipse
- 35:00solution and what it could mean for accuracy.
- 35:02It's a fantastic example of how focusing on precision,
- 35:06even on what seems like a small detail, can have
- 35:08these huge downstream effects in medicine. Absolutely.
- 35:12That relentless pursuit of getting it right,
- 35:15of building a better foundation through accurate
- 35:16measurement, that's how patient care truly advances.
- 35:20one reliable step at a time. We hope you found
- 35:22that insightful. Join us next time for another
- 35:24deep dive, where we'll unpack more sources and
- 35:26extract those crucial insights for you. Until
- 35:29then, stay curious, stay informed.